Make the most of your energySMProducts GuideLighting Control and Integrated Home Systems
Technical InformationInput 120-277Vac +/-10% 50/60 HzOutput 120Vac 277Vac 1000 W max. tungsten
0.75 in.19 mm0.75 in.19 mm4.53 in.115 mm5.98 in.152 mm6.9 in. (173 mm)9.8 in. (246 mm)9.8 in.246 mm6.9 in.173 mm0.9 in. (23.5 mm) 2.2 in. (54 mm)2.9 i
View of the Ethernet Network Interface showing width2.83 in.72 mm2.56 in.65 mm3.35 in.85 mmFront view of the PC Interface showing width2.84 in.72 mmSi
Conduit knockouts for the 8M EnclosureFront view of 8M Enclosure box showing height and widthSide view of 8M Enclosure box showing depthC-BusTM 8M Enc
Front view of the Pascal Automation ControllerSide view of the Pascal Automation Controller2.83 in.72 mmTELEPHONE INTERFACE5.77 in.146.5 mm5.71 in.145
2.6 in.65 mm2.8 in.72 mm3.4 in.85 mm2.83 in.72 mm.59 in.15 mm3.46 in.88 mm1.85 in.47 mm1.97 in.50 mm26 ft8 m8 ft2.4 m13 ft4 m13 ft4 m7 ft2 m7 ft2 m028
Field of view from side of Outdoor Motion SensorField of view from top of Outdoor Motion SensorSide view of Outdoor Motion Sensor5.5 in.140 mm4.5 in.1
POWERNETWORK9 in.230 mm0.4 in.10 mmFront view of DALI GatewayDALI GatewayC-Bus CONNECTIONS2.83 in.72 mmUnit/CommsC-BusDALI1DALI22.83 in.72 mm65 mm85
Front view of the 0-10V Fluorescent Ballast Dimmer2.83 in.72 mmSide view of the 0-10V Fluorescent Ballast Dimmer2.56 in.65 mm3.35 in.85 mmFront view o
Front view of a C-Bus Changeover RelayChangeover Relay2 3 41C-Bus CONNECTIONSUnitC-BusNUSE COPPER WIRE ONLYL NO NCC NO NCCNC NONC NOCC3 41 25.67 in.14
Front view of 12M Enclosure box showing height and width12.78 in.325 mm9.09 in.231 mmFront view of 24M Enclosure box showing height and width14.50 in.
Catalog Number Description Blank Catalog Number Toggle Catalog Number DescriptionSLSUWD1277UW White SLSPWP2DBW SLSPWP2DTW WhiteSLSUWD12
60M Knockouts Symbol Conduit Size Symbol Conduit SizeA ½ E 1 ½B ¾ F 2C 1 G 2 ½D 1 ¼ B,C,D,EAC,D,E,F,GA,BC,D,E,FD,E,
C-BusTM Multi-RoomAudio, Remote Controls and IR Accessories109
Extend the capabilities of a C-Bus system by incorporating award winning C-Bus multi-room audio. Multi-room audio augments a C-Bus lighting control sy
Catalog Number DescriptionSLC560884T Matrix SwitcherTechnical InformationSupply Voltage 120V ACLine Frequency Range 47 to 53 Hz and 57 to 63 Hz AC
Technical InformationSupply Voltage 27Vdc (powered by Matrix Switcher via digital audio connection), and/or 24Vdc @ 3.75 A (via external switch mode
Technical InformationSupply Voltage 27Vdc (powered by Amplier via digital audio connection), or 24Vdc @ 500 mA (via external power pack)Analog Inp
Catalog Number DescriptionSLC5600IWP In-Wall Polypropylene speakersSLC5600IWK In-Wall Kevlar speakersSLC5600ICP In-Ceiling Polypropylene speake
Technical InformationLCD Screen 1.6 in. (W) x 3.6 in. (H) Backlighting Brilliant blue LED Learning Frequency 20 kHz to 455 kHz & pulse Memor
Catalog Number DescriptionSLC5084TX Four Button IR Remote ControllerSLC5088TX Eight Button IR Remote ControllerTechnical InformationSupply Voltag
Technical InformationInput 120-277Vac +/-10% 50/60 Hz Output 120Vac 277Vac 1000 W max. tungsten incandescent load ¼ hp max. m
Catalog Number DescriptionSLC8050TT IR Tube TargetSLC8050ST IR Shelf Mount TargetSLC8050FT IR Flat TargetSLC8050LD IR Emitter Leads- SingleSLC8
0.33 in.8.3 mm11 in.280 mm16.7 in.424 mm13.6 in.346 mm2.6 in.66 mm0.3 in.8 mmFront View2.6 in.66 mm.31 in.8 mm4.1 in.105 mmTop ViewDesktop Model Audio
8.7 in.221 mmWall Mount Speaker Dimensions8.7 in.221 mm12.125 in.308 mm12.125 in.308 mm3.125 in.79 mmOutdoor Speaker Dimensions6.75 in.171 mm6.0 in.15
2.4 in.61 mm8.3 in.210 mm2.1 in52 mm5.9 in149 mm1 in25 mm2.2 in55 mm4.3 in108 mm1.3 in32 mm2.1 in52 mm5.9 in149 mm2.1 in52 mm5.9 in149 mm1 in25 mm2.2
C-BusTM HVAC Controls121
C-BusTM thermostats are used to regulate the air temperature of zones by controlling heating-ventilation-air conditioning (HVAC) equipment.With C-Bus
Catalog Number Description Catalog Number Description SLC5070THBWE Single Zone Thermostat White (no on-board relays) SLC
5.9 in. 150 mm1.26 in. 32 mm4.13 in. 105 mm5.0 in. 127 mm1.06 in. 27 mm3.62 in. 92 mmC-BUSTM CONTROL + TECHNICAL SECTIONC-BusTM Basic Single Zone Th
C-BusTM RF WirelessControls125
Break loose from the cumbersome wiring and associated cost of home control systems with C-Bus™ RF wireless communication. Designed to easily replace s
Catalog Number Description Blank Catalog Number Toggle Catalog Number DescriptionSLSDWD1277UW White SLSPWP2DBW SLSPWP2DTW WhiteSLSDWD12
Technical InformationSupply Voltage 120V AC @ 60 HzRF Frequency 916 MhzTransmitting Power 5 mWTypical Range 80 to 100 ft. (24.4 to 30.5m) in bui
Technical InformationSupply Voltage 120V AC @ 60 HzRF Frequency 916 MhzTransmitting Power 5 mWTypical Range 80 to 100 ft. (24.4 to 30.5m) in bu
Technical InformationSupply Voltage 120V AC @ 60 HzRF Frequency 916 MhzTransmitting Power 5 mWTypical Range 80 to 100 ft. (24.4 to 30.5m) in bu
Catalog Number DescriptionSLC5812R8F1UD Plug Adaptor, 1 Channel Relay 8ASLC5812D5L1UD Plug Adaptor, 1 Channel Leading Edge 60
Technical InformationSupply Voltage 2 x AAA, batteriesRadio Frequency 916 MHzTransmitting Power 10 mWTypical range Wood frame / brick veneer cons
Technical InformationC-BusTM Supply Voltage 15 to 36 V DC, 32 mARF Frequency 916 MhzTransmitting Power 5 mW Typical Range 50 to 65 ft. (15 to 2
.71 in.18 mm2.76 in.70 mm2.99 in.76 mm.35 in.9 mm4.57 in.116 mm2.87 in.73 mm42 mm1.65 in.1.65 in.42 mm2.87 in.73 mm .71 in.18 mm2.76 in.70 mm2.99 in.
5.9 in. 149 mm4.10 in.105 mm5.9 in.149 mm1.0 in.26 mmFront view of GatewayTop view of GatewaySide view of GatewayC-BUSTM WIRELESS CONTROLS + TECHNI
C-BusTM Software135
Residential Control:The C-BusTM HomeGate Software provides residential application PC control of a C-Bus Control System. HomeGate can be accessed from
Catalog Number DescriptionSLSCPS1000 Ceiling Mounted PIR Occupancy Sensor SLSPP1277 Power Pack (required)SLSSP24 Au
* Installer key allows installers to create/commission projects using HomeGate software. This code key is time restricted and allows the software to o
Catalog Number Description SLC5000SDSP24 Schedule Plus license key for 2 networksSLC5000SDSP104 Schedule Plus license key for 10 networksSLC500
Design guide139
Introductiona. OverviewCapabilitiesa. Dimmingb. Multi-scene controlc. Daylighting controld. C-Bus with PowerlinkSpecificationsa. Programming princi
C-BUSTM LIGHTING CONTROL + DESIGN GUIDEI. Introductiona. OverviewII. Capabilities a. Dimming b. Multi-Scene Controlc. Daylighting Controld. C-Bus wi
Illustration of DALI Network ControlIllustration of 0-10V Dimming C-BUSTM LIGHTING CONTROL + DESIGN GUIDELighting Control from Schneider Electric em
C-BUSTM LIGHTING CONTROL + DESIGN GUIDEMulti-Scene ControlPresentation (scene 1) Room Front = Off Room Rear = 50% Table Front = 50% Table Rear =
Illustration of C-Bus Connected to Powerlink G3 PanelWINDOWSDAYLIT AREAZone 1RelayCh-1Zone 2Relay Ch-2C-Bus Multi-SensorC-Bus Multi-SensorC-Bus C-BusZ
Programming PrinciplesAll C-BusTM devices require programming, with the exception of power supplies. Programming is achieved with proprietary software
C-BUSTM LIGHTING CONTROL + DESIGN GUIDEArea AddressingThe area address is a convenient method of addressing multiple output channels collectively.
Technical InformationCurrent Consumption @ 24Vdc1 34mA Nominal (125mA maximum) Supply Voltage 24VdcIsolated Relay 1A @ 24Vdc ResistiveOperating
C-BUSTM LIGHTING CONTROL + DESIGN GUIDEApplication AddressingApplications are used to divide the C-Bus network into independent functional systems.
UnitAddress254UnitAddress253NetworkAddress254NetworkAddress253Network A(Local)Network B(Remote)UnitAddress253UnitAddress252NetworkAddress252Network C(
C-BUSTM LIGHTING CONTROL + DESIGN GUIDEC-BusTM Wiring RulesSchneider Electric C-Bus incorporates a distributed intelligence lighting control system
C-BUSTM LIGHTING CONTROL + DESIGN GUIDEPlanning & Design The most important phase of any Schneider Electric C-BusTM lighting control project is
C-BUSTM LIGHTING CONTROL + DESIGN GUIDEOfces 1-4: Tandem wired 3-lamp uorescent luminaires (32W T8) Lighting power density of 192W/225SF=
C-BUSTM LIGHTING CONTROL + DESIGN GUIDEConf Room: (2) C-BusTM PIR 360° occupancy sensors (1) DLTTMh NeoTM keypad (4) 4A Phase angle dim
C-BusUnit200mA C-Bus Power Supply includedVoltage Free Relay4321C-BUSTM LIGHTING CONTROL + DESIGN GUIDEBill of MaterialCatalog # Description
Table FrontOffice 1 - AOffice 1 - BOffice 2 - AOffice 2 - BOffice 3 - AOffice 3 - BOfce 4 - AOfce 4 - BTable RearRoom FrontRoom Rear C-BUSTM LIGHTIN
Schneider Electric occupancy sensors, Powerlink® and C-Bus™ control systems can be used independently or combined to provide the optimal lighting cont
Schneider Electric Occupancy SensorsOccupancy sensors from Schneider Electric are the perfect solution for applications needing simple occupancy-based
Catalog Number Description SLSCDS2000 Ceiling Mounted Dual Technology Occupancy Sensor SLSPP1277 Power Pack (required) S
C-Bus DIN Rail Mounted Units provide a vast array of capabilities, scalable for virtually any size job, from a single room to an entire home. Dimmers,
RS-232 and Ethernet ConnectionsSecurity, Blind/Shade Control, etc.*Telephone Interface Unit Typical Cat-5 Cable (Any Topology) C-Bus Network Input
Schneider Electric - North American Operating Division 320 Tech Park Drive, Suite 100 LaVergne, TN 37086 Tel: 1-888-SQUARED www.schneider-
Addendum 1200CT0902R01/10 01/2010 Products Guide - Lighting Control and Integrated Home Systems ABOUT THIS ADDENDUM This bulletin appends selection
Products Guide - Lighting Control and Integrated Home Systems Instruction Bulletin Schneider Electric, USA 320 Tech Park Drive, Suite 100 La Vergne,
Technical InformationCurrent Consumption @ 24Vdc1 34mA Nominal (125mA maximum) Supply Voltage 24VdcIsolated Relay 1A @ 24Vdc ResistiveOperating
Catalog Number DescriptionSLSWUS1500 Wall Mounted Occupancy Sensor UltrasonicSLSPP1277 Power Pack (required)SLSSP24
Catalog Number Description SLSWDS1500 Wall Mounted Occupancy Sensor Dual Technology SLSPP1277 Power Pack (required) SLSSP2
Occupancy Sensors 1-22Introduction 1Wall Switch Occupancy Sensors 3Ceiling Mounted Occupancy Sensors 11Wall Mounted Occupancy Sensors 14Power
Technical InformationItem Power Pack Auxiliary RelayStorage Temp -20°F to 150°F (-29C to 65C) -20°F t
Catalog Number Description SLSPIP210 Basic Occupancy Sensor SLSPIP211 Single Output Occupancy SensorSLSPIP212 Dual Output Occupancy SensorSLSPCW0
Sensor featuresSensor eld of viewManualAutoSide view of sensor eld of view6 ft. (1.83 m)9 ft. (2.74 m)21 ft. (6.4 m)35 ft.(10.7 m)35 ft.(10.7 m)4 ft
Side view of ceiling mounted sensor48 ft.42 ft.Area of DetectionMajor MotionMinor Motion24 ft.30 ft.48 ft.42 ft.Area of DetectionMajor MotionMinor Mot
Area of DetectionUltrasonic Major MotionUltrasonic Minor MotionPIR Major MotionPIR Minor Motion48 ft.42 ft.24 ft.30 ft.25 ft.32 ft.4.5 in.(115 mm)1.75
Coverage pattern for area / aisle lenses (side view)Coverage pattern for aisle lens (top view)000Coverage pattern for area lens (top view)3 in.(76 mm)
Track-Limiting Panels23
Energy codes typically require lighting power density calculations for track lighting to be based on the linear feet of installed track. Some codes st
Technical InformationItem Track-Limiting PanelType NEMA 1 IndoorBox Galvanized steelFinish ANSI 49 Gray Voltage Rating 120VacShort Circuit Cu
20AStandard LayoutRevised Layout Using Short Track SegmentsTrack length determines wattage calculationTrack length determines wattage calculationThe S
C-Bus Area Lighting Panels 85-108Introduction 86C-Bus Enclosures 88Technical Section 94C-Bus Multi-room Audio, Remote Controls and IR Accessori
Powerlink®Lighting Control27
For many designers, the engineering of a suitable lighting control system has become a daunting task. The designer must balance space constraints, equ
POWERLINK® LIGHTING CONTROL + PANEL BOARDSInnovative Schneider Electric remote-operated circuit breakers combine the protective features of conventi
POWERLINK® LIGHTING CONTROL + PANEL BOARDSThe NF Panelboard offers superior performance and application exibility for commercial and industrial ele
Technical InformationVoltage 120Vac 240Vac 480/277VacInterrupting capacity 65 kAIR 65 kAIR 14 kAIRTerminals (1) #14 - 8 AL or (1) #14 - 8 CUS
Catalog Number Ampere RatingECB142020G3EL 20 AmpTechnical InformationVoltage 120Vac 240Vac 480/277VacInterrupting capacity 65 kAIR 65 kAI
Technical InformationOperating Temperature 23°F to 104°F (-5°C to 40 °C)(external panelboard ambient)Storage Temperature -4°F to 185°F (–20°C to 8
Catalog Number Voltage Primary Source NF120PSG3 120V Panel BusNF240PSG3 240V Panel Bus NF277PSG3 277V Panel BusNF120PS
Catalog Number Controller TypeNF500G3 500 Level Powerlink G3 ControllerNF1000G3 1000 Level Powerlink G3 Controller NF1000G3N2 1000 Level Powerl
Input Terminals 2-wire 8 16 16 162-wire with status feedback 8 8 8 83-wire 8 8 8 8Input Types2-wire normally open (NO) or normally closed
Occupancy Sensors1
Technical InformationDimensions 12” x 12” x 6” (304.8 mm x 304.8 mm x 152.4 mm) Mounting Wall mount Ethernet Port (1) 10BaseT port Inputs (16)
Catalog Number DescriptionNFSELG3 Slave address selectorNF2HG3 Slave bus connect harnessNFCW3G Column width controller cableNFADAPTERG3 Remote mo
Technical InformationNominal Line Voltage Operates at 120 or 277Vac, ± 10%, with a frequency range from 50–60 Hz Maximum Line Current 9.9 mA fo
Catalog Number DescriptionNFDR120G3C 120V Powerlink Device Router NFDR277G3C 277V Powerlink Device Router Technical InformationNominal Line Vo
125A 12 26 660 18 26 660 30† 32 813 250A 30 38 965 42 44 1118 54 50 1270 100A 12 38 965 (FIL) 18 38 965
POWERLINK® LIGHTING CONTROL + TECHNICAL SECTIONThis table lists the UL short-circuit current ratings for NF panelboards including ECB-G3 circuit brea
POWERLINK® LIGHTING CONTROL + TECHNICAL SECTIONThis section contains wiring diagrams for the Schneider Electric Powerlink® G3 systemsWiring Diagrams
Subnet communications allow one controller tooperate up to 168 remotely operated branch circuits.Automation networks provide remote access to the ligh
POWERLINK® LIGHTING CONTROL + TECHNICAL SECTIONEthernet ConnectivitySchneider Electric Powerlink® G3 2000 and 3000 level controllers have integrated
POWERLINK® LIGHTING CONTROL + TECHNICAL SECTIONBelow is a typical one-line diagram for creating a local area network using the C-BusTM Network capabi
Occupancy sensors help building owners achieve energy savings and energy code compliance with sensors that are easy to select, install and commission.
C-BusTM Lighting Control47
The availability of low-cost, powerful microprocessors for building and home control and management systems has created unprecedented customer expecta
Technical InformationVoltage Requirements 15–36Vdc @ 22 mA required for normal operation, drawn from the C-Bus network Number of Units on a Networ
Technical InformationVoltage Requirements 15–36Vdc @ 22 mA required for normal operation, drawn from the C-Bus networkNumber of Units Determin
Technical InformationVoltage 15–36Vdc @ 22 mA required for normal operation, Requirements drawn from the C-Bus network Number of Units Use the C-
Technical InformationVoltage Requirements 15–36Vdc @ 22 mA required for normal operation, drawn from the C-Bus networkNumber of Units Use the C-Bus
Technical InformationVoltage 15–36Vdc @ 22 mA required for normal operation, Requirements drawn from the C-Bus network Number of Units Determined
Technical InformationVoltage 15–36Vdc @ 22 mA required for normal operation, Requirements drawn from the C-Bus network Number of Units Determined
Technical InformationScreen Type LCD active matrix Size 4.7 in. (119 mm) diagonal Resolution VGA, 320 x 240 pixels Viewing Area Left, right:
Technical InformationScreen AC input impedance 13 K ohms @ 1kHzDisplay type 4.7 inch (119 mm) active black and white LCDl Resolution 320 x 240 pix
Technical InformationInput 120 or 277Vac 60 HzOutput 120Vac 277Vac 1000 W max. incandescent load 1000 VA max. ballast load 1800 VA m
Technical InformationScreen Type LCD active matrix Size 6.4 in. (diagonal) Resolution VGA, 640 x 480 pixels Pixel Pitch 0.01 in. (H) x 0.01 in
Technical InformationC-Bus Voltage Requirements 15–36VdcSupply Current 12V AC or DC @ 300 mA C-Bus Input Voltage 15 to 36V DCDoes not draw current
Catalog Number DescriptionSLC5500PC PC InterfaceTechnical InformationVoltage 15–36Vdc @ 32 mA required for normal operation, Requirements draw
Catalog Number DescriptionSLC5500PCU PC Interface, USB ModelTechnical InformationC-bus input voltage 15-36Vd Current drawn 22mA Electrical is
Catalog Number DescriptionSLC5500NB Network BridgeTechnical InformationVoltage 15–36Vdc @ 18 mA required for normal operation, Requirements dr
Catalog Number DescriptionSLC5500TPS 120Vac Power SupplySLC5500HPS 277Vac Power SupplyTechnical InformationNominal Line Voltage Operates at 120
Technical InformationNominal Line Voltage Operates at 120 or 277Vac, ± 10%, with a frequency range from 50–60 Hz Maximum Line Current 9.9 mA fo
Catalog Number DescriptionNFDR120G3C 120V Powerlink Device Router NFDR277G3C 277V Powerlink Device Router Technical InformationNominal Line V
Technical InformationC-BusTM Supply Voltage 15-36Vdc @ 32 mA Drawn from the C-Bus network RS-232 Supply Voltage 24Vac @ 20 mA (power source not pr
Catalog Number DescriptionSLC5100TUS Telephone Interface Unit Technical InformationC-Bus Supply Voltage 15 36Vdc @ 18 mA Nominal DC Plug Pack 1
Technical InformationInput 120 or 277Vac 60 HzOutput 120Vac 277Vac 1000 W max. incandescent load 1000 VA max. ballast load 1800 VA m
Technical InformationNominal Voltage Requirements 15-36 volts @18 mA from the C-Bus networkNominal 120VacNominal Supply Voltage 16-27V AC/DC, +/
Catalog Number DescriptionSLC5102BCLEDL Two-Channel Bus CouplerSLC5104BCL Four-Channel Bus CouplerTechnical InformationNominal Voltage 15-36Vdc @
Catalog Number DescriptionSLCLE5504AUX 4 Channel Auxiliary Input UnitTechnical InformationNominal Voltage Requirements 15-36Vdc @
Technical InformationNominal Voltage Requirements 15-36Vdc @ 18 mA, drawn from the C-Bus networkField of View 90° PIR Detection
Technical InformationNominal Voltage Requirements 15-36Vdc @ 18 mA, drawn from the C-Bus network Field of View 360° PIR Rated
Catalog Number Description AccessoriesSLC5753PEIRL 360° PIR Multi-Sensor SLC5084TX IR 4-Button Remote Controller (ordered sepa
Technical InformationNominal Voltage Requirements 15-36Vdc @ 18 mA, drawn from the C-Bus networkField of View 110° PIR Detec
Technical InformationNominal Voltage Requirements 15-36Vdc @ 18 mA, drawn from the C-Bus network Light Level Reads: 2-278 foot
Technical InformationNominal Voltage Requirements 15–36Vdc @ 18 mA, drawn from the C-Bus network Field of View 180°Light-Leve
Catalog Number Description Accessories DescriptionSLC5104TD5 Professional Dimmer 5A, 4 Channel, 120Vac SLCU5100TB Termina
Technical Information Input 120-277Vac +/-10% 50/60 Hz Output 120Vac 277Vac 1000 W max. tungsten incan
Technical InformationNominal Voltage Requirements 15–36Vdc @ 18 mA from the C-Bus network
Technical InformationNominal Voltage Requirements 15-36Vdc @ 32 mA, drawn from the C-Bus network Electrical Isolation 3.75 kV R
Technical InformationPower Requirements C-Bus: 15–36Vdc @ 22 mA required for normal operation. Power: 120V or 277Vac connection, 10 W Number of Un
Catalog Number DescriptionSLC5504TRVF 4 Channel, 120V, 10A w/power supplySLC5504TRVFP 4 Channel, 120V, 10A w/o power supplySLC5504HRVF 4 Channel,
Technical Information Nominal Supply Voltage 110-120V (SLC5504TRVF20 and SLC5504TRVF20P) 277V (SLC5504HRVF20 and SLC5504HRVF20P) Frequency Range(s
Catalog Number DescriptionSLC5504TRVFC 4 Channel changeover relay unit 120Vac, with power supplySLC5504TRVFCP 4 Channel changeover relay unit 120Va
Technical InformationC-Bus network supply voltage 15 to 36Vdc @ 32mA required for programming and operationMaximum units per C-Bus network
C-BusTM Enclosures and Area Lighting Panels85
Area lighting panels from Schneider Electric are a simple, convenient way to area dimming and multi-scene controls, as well as daylight harvesting sch
Catalog Number Description Blank Catalog Number Toggle Catalog Number DescriptionSLSPWD1277UW White SLSPWP2DBW SLSPWP2DTW WhiteSLSPWD12
Technical InformationRated Voltage 120V & 277V 50/60Hz Number of Units Use the C-Bus calculator, a software utility to per Network determin
Catalog Number Description AccessoriesSLC8M 8M DIN Enclosure* PK7GTA Ground/Neutral Bar† PKGTAB Neutral Insulator Kit†
Technical Information12M Enclosure Type NEMA 1 DIN Module Capacity One 12M, one 8M + one 4M or three 4M C-Bus units Dimensions 12.78 in. (
Catalog Number Description AccessoriesSLC24MSG 24M DIN Enclosure* PK7GTA Ground/Neutral Bar† PKGTAB Neutral Insulator Kit†
Catalog Number Description AccessoriesSLC36C Enclosure Cabinet, 40 in. PK18GTA Neutral bar, 18 terminal1,2,3 SLC36
Catalog Number Description AccessoriesSLC36SC Enclosure Cabinet PK7GTA Grnd/Neutral SLCMSFG Flush Mount Gray PKGTAB N
Technical Information60M Enclosure Type NEMA Type 1 DIN Module Capacity Five DIN rails, each with the capacity for one 12M, one 8M with one 4
Illustration shows: Inner Surround (A), Outer Surround (B) and Button Covers (C)C-BUSTM LIGHTING CONTROL + TECHNICAL SECTIONKeypad AssembliesOrder n
.63 in.16 mm2.64 in.67 mm2.05 in.52 mm.24 in.6 mm3.0 in.76 mm4.57 in.116 mm3.0 in.76 mm4.57 in.116 mm3.0 in.76 mm4.57 in.116 mm0.51 in.13 mm0.71 in.18
Front and top-side views of the Saturn DLT keypad illustrate its length and width and the depth the case extends into and out of a wall.43 in.10.8 mm1
Comments to this Manuals