Schneider Electric SLC560125D Technical Information

Browse online or download Technical Information for Audio amplifiers Schneider Electric SLC560125D. Schneider Electric SLC560125D Technical information User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 166
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - Products Guide

Make the most of your energySMProducts GuideLighting Control and Integrated Home Systems

Page 2

Technical InformationInput 120-277Vac +/-10% 50/60 HzOutput 120Vac 277Vac 1000 W max. tungsten

Page 3

0.75 in.19 mm0.75 in.19 mm4.53 in.115 mm5.98 in.152 mm6.9 in. (173 mm)9.8 in. (246 mm)9.8 in.246 mm6.9 in.173 mm0.9 in. (23.5 mm) 2.2 in. (54 mm)2.9 i

Page 4 - Occupancy Sensors

View of the Ethernet Network Interface showing width2.83 in.72 mm2.56 in.65 mm3.35 in.85 mmFront view of the PC Interface showing width2.84 in.72 mmSi

Page 5

Conduit knockouts for the 8M EnclosureFront view of 8M Enclosure box showing height and widthSide view of 8M Enclosure box showing depthC-BusTM 8M Enc

Page 6 - Occupancy Sensor

Front view of the Pascal Automation ControllerSide view of the Pascal Automation Controller2.83 in.72 mmTELEPHONE INTERFACE5.77 in.146.5 mm5.71 in.145

Page 7 - Occupancy Sensor w/Manual On

2.6 in.65 mm2.8 in.72 mm3.4 in.85 mm2.83 in.72 mm.59 in.15 mm3.46 in.88 mm1.85 in.47 mm1.97 in.50 mm26 ft8 m8 ft2.4 m13 ft4 m13 ft4 m7 ft2 m7 ft2 m028

Page 8

Field of view from side of Outdoor Motion SensorField of view from top of Outdoor Motion SensorSide view of Outdoor Motion Sensor5.5 in.140 mm4.5 in.1

Page 9

POWERNETWORK9 in.230 mm0.4 in.10 mmFront view of DALI GatewayDALI GatewayC-Bus CONNECTIONS2.83 in.72 mmUnit/CommsC-BusDALI1DALI22.83 in.72 mm65 mm85

Page 10 - Product Features

Front view of the 0-10V Fluorescent Ballast Dimmer2.83 in.72 mmSide view of the 0-10V Fluorescent Ballast Dimmer2.56 in.65 mm3.35 in.85 mmFront view o

Page 11

Front view of a C-Bus Changeover RelayChangeover Relay2 3 41C-Bus CONNECTIONSUnitC-BusNUSE COPPER WIRE ONLYL NO NCC NO NCCNC NONC NOCC3 41 25.67 in.14

Page 12

Front view of 12M Enclosure box showing height and width12.78 in.325 mm9.09 in.231 mmFront view of 24M Enclosure box showing height and width14.50 in.

Page 13

Catalog Number Description Blank Catalog Number Toggle Catalog Number DescriptionSLSUWD1277UW White SLSPWP2DBW SLSPWP2DTW WhiteSLSUWD12

Page 14

60M Knockouts Symbol Conduit Size Symbol Conduit SizeA ½ E 1 ½B ¾ F 2C 1 G 2 ½D 1 ¼ B,C,D,EAC,D,E,F,GA,BC,D,E,FD,E,

Page 16 - Dual Technology

C-BusTM Multi-RoomAudio, Remote Controls and IR Accessories109

Page 17 - Wall Mounted Occupancy Sensor

Extend the capabilities of a C-Bus system by incorporating award winning C-Bus multi-room audio. Multi-room audio augments a C-Bus lighting control sy

Page 18

Catalog Number DescriptionSLC560884T Matrix SwitcherTechnical InformationSupply Voltage 120V ACLine Frequency Range 47 to 53 Hz and 57 to 63 Hz AC

Page 19

Technical InformationSupply Voltage 27Vdc (powered by Matrix Switcher via digital audio connection), and/or 24Vdc @ 3.75 A (via external switch mode

Page 20

Technical InformationSupply Voltage 27Vdc (powered by Amplier via digital audio connection), or 24Vdc @ 500 mA (via external power pack)Analog Inp

Page 21 - High Bay Occupancy Sensor

Catalog Number DescriptionSLC5600IWP In-Wall Polypropylene speakersSLC5600IWK In-Wall Kevlar speakersSLC5600ICP In-Ceiling Polypropylene speake

Page 22 - Ultrasonic Wall Switch

Technical InformationLCD Screen 1.6 in. (W) x 3.6 in. (H) Backlighting Brilliant blue LED Learning Frequency 20 kHz to 455 kHz & pulse Memor

Page 23 - TECHNICAL SECTION

Catalog Number DescriptionSLC5084TX Four Button IR Remote ControllerSLC5088TX Eight Button IR Remote ControllerTechnical InformationSupply Voltag

Page 24

Technical InformationInput 120-277Vac +/-10% 50/60 Hz Output 120Vac 277Vac 1000 W max. tungsten incandescent load ¼ hp max. m

Page 25 - High Bay Occupancy Sensors

Catalog Number DescriptionSLC8050TT IR Tube TargetSLC8050ST IR Shelf Mount TargetSLC8050FT IR Flat TargetSLC8050LD IR Emitter Leads- SingleSLC8

Page 26 - Track-Limiting

0.33 in.8.3 mm11 in.280 mm16.7 in.424 mm13.6 in.346 mm2.6 in.66 mm0.3 in.8 mmFront View2.6 in.66 mm.31 in.8 mm4.1 in.105 mmTop ViewDesktop Model Audio

Page 27 - Track-Limiting Panels

8.7 in.221 mmWall Mount Speaker Dimensions8.7 in.221 mm12.125 in.308 mm12.125 in.308 mm3.125 in.79 mmOutdoor Speaker Dimensions6.75 in.171 mm6.0 in.15

Page 28

2.4 in.61 mm8.3 in.210 mm2.1 in52 mm5.9 in149 mm1 in25 mm2.2 in55 mm4.3 in108 mm1.3 in32 mm2.1 in52 mm5.9 in149 mm2.1 in52 mm5.9 in149 mm1 in25 mm2.2

Page 30 - Lighting Control

C-BusTM thermostats are used to regulate the air temperature of zones by controlling heating-ventilation-air conditioning (HVAC) equipment.With C-Bus

Page 31

Catalog Number Description Catalog Number Description SLC5070THBWE Single Zone Thermostat White (no on-board relays) SLC

Page 32 - G3 Panel Mounted Components

5.9 in. 150 mm1.26 in. 32 mm4.13 in. 105 mm5.0 in. 127 mm1.06 in. 27 mm3.62 in. 92 mmC-BUSTM CONTROL + TECHNICAL SECTIONC-BusTM Basic Single Zone Th

Page 33 - & Custom Panel Boards

C-BusTM RF WirelessControls125

Page 34

Break loose from the cumbersome wiring and associated cost of home control systems with C-Bus™ RF wireless communication. Designed to easily replace s

Page 35

Catalog Number Description Blank Catalog Number Toggle Catalog Number DescriptionSLSDWD1277UW White SLSPWP2DBW SLSPWP2DTW WhiteSLSDWD12

Page 36 - G3 Control Bus

Technical InformationSupply Voltage 120V AC @ 60 HzRF Frequency 916 MhzTransmitting Power 5 mWTypical Range 80 to 100 ft. (24.4 to 30.5m) in bui

Page 37

Technical InformationSupply Voltage 120V AC @ 60 HzRF Frequency 916 MhzTransmitting Power 5 mWTypical Range 80 to 100 ft. (24.4 to 30.5m) in bu

Page 38 - Controllers

Technical InformationSupply Voltage 120V AC @ 60 HzRF Frequency 916 MhzTransmitting Power 5 mWTypical Range 80 to 100 ft. (24.4 to 30.5m) in bu

Page 39 - - X X X

Catalog Number DescriptionSLC5812R8F1UD  Plug Adaptor, 1 Channel Relay 8ASLC5812D5L1UD Plug Adaptor, 1 Channel Leading Edge 60

Page 40 - Remote Source Controller

Technical InformationSupply Voltage 2 x AAA, batteriesRadio Frequency 916 MHzTransmitting Power 10 mWTypical range Wood frame / brick veneer cons

Page 41 - Accessories

Technical InformationC-BusTM Supply Voltage 15 to 36 V DC, 32 mARF Frequency 916 MhzTransmitting Power 5 mW Typical Range 50 to 65 ft. (15 to 2

Page 42 - Device Power Supply

.71 in.18 mm2.76 in.70 mm2.99 in.76 mm.35 in.9 mm4.57 in.116 mm2.87 in.73 mm42 mm1.65 in.1.65 in.42 mm2.87 in.73 mm .71 in.18 mm2.76 in.70 mm2.99 in.

Page 43 - Device Router

5.9 in. 149 mm4.10 in.105 mm5.9 in.149 mm1.0 in.26 mmFront view of GatewayTop view of GatewaySide view of GatewayC-BUSTM WIRELESS CONTROLS + TECHNI

Page 45

Residential Control:The C-BusTM HomeGate Software provides residential application PC control of a C-Bus Control System. HomeGate can be accessed from

Page 46 - Wiring Diagrams

Catalog Number DescriptionSLSCPS1000 Ceiling Mounted PIR Occupancy Sensor SLSPP1277 Power Pack (required)SLSSP24 Au

Page 47 - System Architecture

* Installer key allows installers to create/commission projects using HomeGate software. This code key is time restricted and allows the software to o

Page 48 - Remote Source Controller

Catalog Number Description SLC5000SDSP24 Schedule Plus license key for 2 networksSLC5000SDSP104 Schedule Plus license key for 10 networksSLC500

Page 49 - Network

Design guide139

Page 50 - Lighting

Introductiona. OverviewCapabilitiesa. Dimmingb. Multi-scene controlc. Daylighting controld. C-Bus with PowerlinkSpecificationsa. Programming princi

Page 51 - Lighting Control

C-BUSTM LIGHTING CONTROL + DESIGN GUIDEI. Introductiona. OverviewII. Capabilities a. Dimming b. Multi-Scene Controlc. Daylighting Controld. C-Bus wi

Page 52 - Neo™ Keypads

Illustration of DALI Network ControlIllustration of 0-10V Dimming C-BUSTM LIGHTING CONTROL + DESIGN GUIDELighting Control from Schneider Electric em

Page 53 - Keypads

C-BUSTM LIGHTING CONTROL + DESIGN GUIDEMulti-Scene ControlPresentation (scene 1) Room Front = Off Room Rear = 50% Table Front = 50% Table Rear =

Page 54

Illustration of C-Bus Connected to Powerlink G3 PanelWINDOWSDAYLIT AREAZone 1RelayCh-1Zone 2Relay Ch-2C-Bus Multi-SensorC-Bus Multi-SensorC-Bus C-BusZ

Page 55 - Saturn™ Keypads

Programming PrinciplesAll C-BusTM devices require programming, with the exception of power supplies. Programming is achieved with proprietary software

Page 56 - Decorator Style Keypads

C-BUSTM LIGHTING CONTROL + DESIGN GUIDEArea AddressingThe area address is a convenient method of addressing multiple output channels collectively.

Page 57 - Saturn™

Technical InformationCurrent Consumption @ 24Vdc1 34mA Nominal (125mA maximum) Supply Voltage 24VdcIsolated Relay 1A @ 24Vdc ResistiveOperating

Page 58 - Touch Screen

C-BUSTM LIGHTING CONTROL + DESIGN GUIDEApplication AddressingApplications are used to divide the C-Bus network into independent functional systems.

Page 59 - Desktop Touch Screen

UnitAddress254UnitAddress253NetworkAddress254NetworkAddress253Network A(Local)Network B(Remote)UnitAddress253UnitAddress252NetworkAddress252Network C(

Page 60

C-BUSTM LIGHTING CONTROL + DESIGN GUIDEC-BusTM Wiring RulesSchneider Electric C-Bus incorporates a distributed intelligence lighting control system

Page 61

C-BUSTM LIGHTING CONTROL + DESIGN GUIDEPlanning & Design The most important phase of any Schneider Electric C-BusTM lighting control project is

Page 62

C-BUSTM LIGHTING CONTROL + DESIGN GUIDEOfces 1-4: Tandem wired 3-lamp uorescent luminaires (32W T8) Lighting power density of 192W/225SF=

Page 63 - PC Interface USB

C-BUSTM LIGHTING CONTROL + DESIGN GUIDEConf Room: (2) C-BusTM PIR 360° occupancy sensors (1) DLTTMh NeoTM keypad (4) 4A Phase angle dim

Page 64

C-BusUnit200mA C-Bus Power Supply includedVoltage Free Relay4321C-BUSTM LIGHTING CONTROL + DESIGN GUIDEBill of MaterialCatalog # Description

Page 65

Table FrontOffice 1 - AOffice 1 - BOffice 2 - AOffice 2 - BOffice 3 - AOffice 3 - BOfce 4 - AOfce 4 - BTable RearRoom FrontRoom Rear C-BUSTM LIGHTIN

Page 66

Schneider Electric occupancy sensors, Powerlink® and C-Bus™ control systems can be used independently or combined to provide the optimal lighting cont

Page 67

Schneider Electric Occupancy SensorsOccupancy sensors from Schneider Electric are the perfect solution for applications needing simple occupancy-based

Page 68 - Pascal Automation Controller

Catalog Number Description SLSCDS2000 Ceiling Mounted Dual Technology Occupancy Sensor SLSPP1277 Power Pack (required) S

Page 69

C-Bus DIN Rail Mounted Units provide a vast array of capabilities, scalable for virtually any size job, from a single room to an entire home. Dimmers,

Page 70

RS-232 and Ethernet ConnectionsSecurity, Blind/Shade Control, etc.*Telephone Interface Unit Typical Cat-5 Cable (Any Topology) C-Bus Network Input

Page 73

Schneider Electric - North American Operating Division 320 Tech Park Drive, Suite 100 LaVergne, TN 37086 Tel: 1-888-SQUARED www.schneider-

Page 74 - 360° PIR Occupancy Sensor

Addendum 1200CT0902R01/10 01/2010 Products Guide - Lighting Control and Integrated Home Systems ABOUT THIS ADDENDUM This bulletin appends selection

Page 75 - 360° PIR Multi-Sensor

Products Guide - Lighting Control and Integrated Home Systems Instruction Bulletin Schneider Electric, USA 320 Tech Park Drive, Suite 100 La Vergne,

Page 76

Technical InformationCurrent Consumption @ 24Vdc1 34mA Nominal (125mA maximum) Supply Voltage 24VdcIsolated Relay 1A @ 24Vdc ResistiveOperating

Page 77

Catalog Number DescriptionSLSWUS1500 Wall Mounted Occupancy Sensor UltrasonicSLSPP1277 Power Pack (required)SLSSP24

Page 78

Catalog Number Description SLSWDS1500 Wall Mounted Occupancy Sensor Dual Technology SLSPP1277 Power Pack (required) SLSSP2

Page 79

Occupancy Sensors 1-22Introduction 1Wall Switch Occupancy Sensors 3Ceiling Mounted Occupancy Sensors 11Wall Mounted Occupancy Sensors 14Power

Page 80 - Phase Angle Dimmers

Technical InformationItem Power Pack Auxiliary RelayStorage Temp -20°F to 150°F (-29C to 65C) -20°F t

Page 81

Catalog Number Description SLSPIP210 Basic Occupancy Sensor SLSPIP211 Single Output Occupancy SensorSLSPIP212 Dual Output Occupancy SensorSLSPCW0

Page 82

Sensor featuresSensor eld of viewManualAutoSide view of sensor eld of view6 ft. (1.83 m)9 ft. (2.74 m)21 ft. (6.4 m)35 ft.(10.7 m)35 ft.(10.7 m)4 ft

Page 83

Side view of ceiling mounted sensor48 ft.42 ft.Area of DetectionMajor MotionMinor Motion24 ft.30 ft.48 ft.42 ft.Area of DetectionMajor MotionMinor Mot

Page 84

Area of DetectionUltrasonic Major MotionUltrasonic Minor MotionPIR Major MotionPIR Minor Motion48 ft.42 ft.24 ft.30 ft.25 ft.32 ft.4.5 in.(115 mm)1.75

Page 85

Coverage pattern for area / aisle lenses (side view)Coverage pattern for aisle lens (top view)000Coverage pattern for area lens (top view)3 in.(76 mm)

Page 86 - Low Voltage Relay

Track-Limiting Panels23

Page 87

Energy codes typically require lighting power density calculations for track lighting to be based on the linear feet of installed track. Some codes st

Page 88 - Enclosures

Technical InformationItem Track-Limiting PanelType NEMA 1 IndoorBox Galvanized steelFinish ANSI 49 Gray Voltage Rating 120VacShort Circuit Cu

Page 89 - Area Lighting Panels

20AStandard LayoutRevised Layout Using Short Track SegmentsTrack length determines wattage calculationTrack length determines wattage calculationThe S

Page 90

C-Bus Area Lighting Panels 85-108Introduction 86C-Bus Enclosures 88Technical Section 94C-Bus Multi-room Audio, Remote Controls and IR Accessori

Page 91

Powerlink®Lighting Control27

Page 92

For many designers, the engineering of a suitable lighting control system has become a daunting task. The designer must balance space constraints, equ

Page 93

POWERLINK® LIGHTING CONTROL + PANEL BOARDSInnovative Schneider Electric remote-operated circuit breakers combine the protective features of conventi

Page 94 - 36M Enclosures

POWERLINK® LIGHTING CONTROL + PANEL BOARDSThe NF Panelboard offers superior performance and application exibility for commercial and industrial ele

Page 95 - 36MS Enclosures

Technical InformationVoltage 120Vac 240Vac 480/277VacInterrupting capacity 65 kAIR 65 kAIR 14 kAIRTerminals (1) #14 - 8 AL or (1) #14 - 8 CUS

Page 96 - 60M Enclosures

Catalog Number Ampere RatingECB142020G3EL 20 AmpTechnical InformationVoltage 120Vac 240Vac 480/277VacInterrupting capacity 65 kAIR 65 kAI

Page 97 - Keypad Assemblies Standard

Technical InformationOperating Temperature 23°F to 104°F (-5°C to 40 °C)(external panelboard ambient)Storage Temperature -4°F to 185°F (–20°C to 8

Page 98

Catalog Number Voltage Primary Source NF120PSG3 120V Panel BusNF240PSG3 240V Panel Bus NF277PSG3 277V Panel BusNF120PS

Page 99 - Neo™ Style Decorator Keypads

Catalog Number Controller TypeNF500G3 500 Level Powerlink G3 ControllerNF1000G3 1000 Level Powerlink G3 Controller NF1000G3N2 1000 Level Powerl

Page 100 - Mark II Desktop Touch Screen

Input Terminals 2-wire 8 16 16 162-wire with status feedback 8 8 8 83-wire 8 8 8 8Input Types2-wire normally open (NO) or normally closed

Page 101 - PC Interface

Occupancy Sensors1

Page 102 - Network Bridge

Technical InformationDimensions 12” x 12” x 6” (304.8 mm x 304.8 mm x 152.4 mm) Mounting Wall mount Ethernet Port (1) 10BaseT port Inputs (16)

Page 103 - General Input Unit

Catalog Number DescriptionNFSELG3 Slave address selectorNF2HG3 Slave bus connect harnessNFCW3G Column width controller cableNFADAPTERG3 Remote mo

Page 104 - Indoor PIR Occupancy Sensor

Technical InformationNominal Line Voltage Operates at 120 or 277Vac, ± 10%, with a frequency range from 50–60 Hz Maximum Line Current 9.9 mA fo

Page 105 - Outdoor Light-Level Sensor

Catalog Number DescriptionNFDR120G3C 120V Powerlink Device Router NFDR277G3C 277V Powerlink Device Router Technical InformationNominal Line Vo

Page 106 - 2 Channel DALI Gateway

125A 12 26 660 18 26 660 30† 32 813 250A 30 38 965 42 44 1118 54 50 1270 100A 12 38 965 (FIL) 18 38 965

Page 107 - 20 Amp Relay Units

POWERLINK® LIGHTING CONTROL + TECHNICAL SECTIONThis table lists the UL short-circuit current ratings for NF panelboards including ECB-G3 circuit brea

Page 108 - Low Voltage Relay 8 Channel

POWERLINK® LIGHTING CONTROL + TECHNICAL SECTIONThis section contains wiring diagrams for the Schneider Electric Powerlink® G3 systemsWiring Diagrams

Page 109 - 36M Enclosure

Subnet communications allow one controller tooperate up to 168 remotely operated branch circuits.Automation networks provide remote access to the ligh

Page 110 - 36MS Enclosure

POWERLINK® LIGHTING CONTROL + TECHNICAL SECTIONEthernet ConnectivitySchneider Electric Powerlink® G3 2000 and 3000 level controllers have integrated

Page 111

POWERLINK® LIGHTING CONTROL + TECHNICAL SECTIONBelow is a typical one-line diagram for creating a local area network using the C-BusTM Network capabi

Page 112 - Audio, Remote Controls

Occupancy sensors help building owners achieve energy savings and energy code compliance with sensors that are easy to select, install and commission.

Page 113 - IR Accessories

C-BusTM Lighting Control47

Page 114 - Matrix Switcher

The availability of low-cost, powerful microprocessors for building and home control and management systems has created unprecedented customer expecta

Page 115 - Multi-Room Amplifiers

Technical InformationVoltage Requirements 15–36Vdc @ 22 mA required for normal operation, drawn from the C-Bus network Number of Units on a Networ

Page 116 - Audio Distribution Unit

Technical InformationVoltage Requirements 15–36Vdc @ 22 mA required for normal operation, drawn from the C-Bus networkNumber of Units Determin

Page 117 - Audio Speakers

Technical InformationVoltage 15–36Vdc @ 22 mA required for normal operation, Requirements drawn from the C-Bus network Number of Units Use the C-

Page 118 - Universal Remote

Technical InformationVoltage Requirements 15–36Vdc @ 22 mA required for normal operation, drawn from the C-Bus networkNumber of Units Use the C-Bus

Page 119 - Distributed Intelligence

Technical InformationVoltage 15–36Vdc @ 22 mA required for normal operation, Requirements drawn from the C-Bus network Number of Units Determined

Page 120

Technical InformationVoltage 15–36Vdc @ 22 mA required for normal operation, Requirements drawn from the C-Bus network Number of Units Determined

Page 121

Technical InformationScreen Type LCD active matrix Size 4.7 in. (119 mm) diagonal Resolution VGA, 320 x 240 pixels Viewing Area Left, right:

Page 122

Technical InformationScreen AC input impedance 13 K ohms @ 1kHzDisplay type 4.7 inch (119 mm) active black and white LCDl Resolution 320 x 240 pix

Page 123 - Universal Remote

Technical InformationInput 120 or 277Vac 60 HzOutput 120Vac 277Vac 1000 W max. incandescent load 1000 VA max. ballast load 1800 VA m

Page 124 - Controls

Technical InformationScreen Type LCD active matrix Size 6.4 in. (diagonal) Resolution VGA, 640 x 480 pixels Pixel Pitch 0.01 in. (H) x 0.01 in

Page 125 - HVAC Controls

Technical InformationC-Bus Voltage Requirements 15–36VdcSupply Current 12V AC or DC @ 300 mA C-Bus Input Voltage 15 to 36V DCDoes not draw current

Page 126 - CONTROL

Catalog Number DescriptionSLC5500PC PC InterfaceTechnical InformationVoltage 15–36Vdc @ 32 mA required for normal operation, Requirements draw

Page 127 - TECHNICAL SECTION

Catalog Number DescriptionSLC5500PCU PC Interface, USB ModelTechnical InformationC-bus input voltage 15-36Vd Current drawn 22mA Electrical is

Page 128 - RF Wireless

Catalog Number DescriptionSLC5500NB Network BridgeTechnical InformationVoltage 15–36Vdc @ 18 mA required for normal operation, Requirements dr

Page 129 - Wireless Controls

Catalog Number DescriptionSLC5500TPS 120Vac Power SupplySLC5500HPS 277Vac Power SupplyTechnical InformationNominal Line Voltage Operates at 120

Page 130 - 600W RF Dimmers

Technical InformationNominal Line Voltage Operates at 120 or 277Vac, ± 10%, with a frequency range from 50–60 Hz Maximum Line Current 9.9 mA fo

Page 131 - 1000W RF Dimmers

Catalog Number DescriptionNFDR120G3C 120V Powerlink Device Router NFDR277G3C 277V Powerlink Device Router Technical InformationNominal Line V

Page 132

Technical InformationC-BusTM Supply Voltage 15-36Vdc @ 32 mA Drawn from the C-Bus network RS-232 Supply Voltage 24Vac @ 20 mA (power source not pr

Page 133 - Plug Adaptors

Catalog Number DescriptionSLC5100TUS Telephone Interface Unit Technical InformationC-Bus Supply Voltage 15 36Vdc @ 18 mA Nominal DC Plug Pack 1

Page 134 - RF Remote Control

Technical InformationInput 120 or 277Vac 60 HzOutput 120Vac 277Vac 1000 W max. incandescent load 1000 VA max. ballast load 1800 VA m

Page 135 - Wireless Gateway

Technical InformationNominal Voltage Requirements 15-36 volts @18 mA from the C-Bus networkNominal 120VacNominal Supply Voltage 16-27V AC/DC, +/

Page 136 - TECHNICAL SECTION

Catalog Number DescriptionSLC5102BCLEDL Two-Channel Bus CouplerSLC5104BCL Four-Channel Bus CouplerTechnical InformationNominal Voltage 15-36Vdc @

Page 137

Catalog Number DescriptionSLCLE5504AUX 4 Channel Auxiliary Input UnitTechnical InformationNominal Voltage Requirements 15-36Vdc @

Page 138 - Software

Technical InformationNominal Voltage Requirements 15-36Vdc @ 18 mA, drawn from the C-Bus networkField of View 90° PIR Detection

Page 139

Technical InformationNominal Voltage Requirements 15-36Vdc @ 18 mA, drawn from the C-Bus network Field of View 360° PIR Rated

Page 140 - HomeGate

Catalog Number Description AccessoriesSLC5753PEIRL 360° PIR Multi-Sensor SLC5084TX IR 4-Button Remote Controller (ordered sepa

Page 141 - Schedule Plus

Technical InformationNominal Voltage Requirements 15-36Vdc @ 18 mA, drawn from the C-Bus networkField of View 110° PIR Detec

Page 142 - Design guide

Technical InformationNominal Voltage Requirements 15-36Vdc @ 18 mA, drawn from the C-Bus network Light Level Reads: 2-278 foot

Page 143 - Design guide contents

Technical InformationNominal Voltage Requirements 15–36Vdc @ 18 mA, drawn from the C-Bus network Field of View 180°Light-Leve

Page 144 - Contents

Catalog Number Description Accessories DescriptionSLC5104TD5 Professional Dimmer 5A, 4 Channel, 120Vac SLCU5100TB Termina

Page 145 - Introduction

Technical Information Input 120-277Vac +/-10% 50/60 Hz Output 120Vac 277Vac 1000 W max. tungsten incan

Page 146 - Multi-Scene Control

Technical InformationNominal Voltage Requirements 15–36Vdc @ 18 mA from the C-Bus network

Page 147 - Daylighting Control

Technical InformationNominal Voltage Requirements 15-36Vdc @ 32 mA, drawn from the C-Bus network Electrical Isolation 3.75 kV R

Page 148 - Specifications

Technical InformationPower Requirements C-Bus: 15–36Vdc @ 22 mA required for normal operation. Power: 120V or 277Vac connection, 10 W Number of Un

Page 149 - Area Addressing

Catalog Number DescriptionSLC5504TRVF 4 Channel, 120V, 10A w/power supplySLC5504TRVFP 4 Channel, 120V, 10A w/o power supplySLC5504HRVF 4 Channel,

Page 150 - Application Addressing

Technical Information Nominal Supply Voltage 110-120V (SLC5504TRVF20 and SLC5504TRVF20P) 277V (SLC5504HRVF20 and SLC5504HRVF20P) Frequency Range(s

Page 151 - Network Addressing

Catalog Number DescriptionSLC5504TRVFC 4 Channel changeover relay unit 120Vac, with power supplySLC5504TRVFCP 4 Channel changeover relay unit 120Va

Page 152 - DESIGN GUIDE

Technical InformationC-Bus network supply voltage 15 to 36Vdc @ 32mA required for programming and operationMaximum units per C-Bus network

Page 154 - Design Project

C-BusTM Enclosures and Area Lighting Panels85

Page 155 - DESIGN GUIDE

Area lighting panels from Schneider Electric are a simple, convenient way to area dimming and multi-scene controls, as well as daylight harvesting sch

Page 156 - Bill of Material

Catalog Number Description Blank Catalog Number Toggle Catalog Number DescriptionSLSPWD1277UW White SLSPWP2DBW SLSPWP2DTW WhiteSLSPWD12

Page 157 - Finished Design

Technical InformationRated Voltage 120V & 277V 50/60Hz Number of Units Use the C-Bus calculator, a software utility to per Network determin

Page 158 - One-line Diagram

Catalog Number Description AccessoriesSLC8M 8M DIN Enclosure* PK7GTA Ground/Neutral Bar† PKGTAB Neutral Insulator Kit†

Page 159

Technical Information12M Enclosure Type NEMA 1 DIN Module Capacity One 12M, one 8M + one 4M or three 4M C-Bus units Dimensions 12.78 in. (

Page 160

Catalog Number Description AccessoriesSLC24MSG 24M DIN Enclosure* PK7GTA Ground/Neutral Bar† PKGTAB Neutral Insulator Kit†

Page 161

Catalog Number Description AccessoriesSLC36C Enclosure Cabinet, 40 in. PK18GTA Neutral bar, 18 terminal1,2,3 SLC36

Page 162

Catalog Number Description AccessoriesSLC36SC Enclosure Cabinet PK7GTA Grnd/Neutral SLCMSFG Flush Mount Gray PKGTAB N

Page 163

Technical Information60M Enclosure Type NEMA Type 1 DIN Module Capacity Five DIN rails, each with the capacity for one 12M, one 8M with one 4

Page 164 - www.schneider-electric.us

Illustration shows: Inner Surround (A), Outer Surround (B) and Button Covers (C)C-BUSTM LIGHTING CONTROL + TECHNICAL SECTIONKeypad AssembliesOrder n

Page 165 - Systems

.63 in.16 mm2.64 in.67 mm2.05 in.52 mm.24 in.6 mm3.0 in.76 mm4.57 in.116 mm3.0 in.76 mm4.57 in.116 mm3.0 in.76 mm4.57 in.116 mm0.51 in.13 mm0.71 in.18

Page 166

Front and top-side views of the Saturn DLT keypad illustrate its length and width and the depth the case extends into and out of a wall.43 in.10.8 mm1

Comments to this Manuals