Schneider Electric INTERBUS Basic User Manual

Browse online or download User Manual for Networking Schneider Electric INTERBUS Basic. Modicon TSX Momentum Interbus Communication Adapter User

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - User Guide

709606.20Breite: 178 mmHöhe: 216 mmModicon TSX MomentumInterbus Communication AdapterUser Guide870 USE 003 0010/97

Page 2

Interbus with TSX Momentum Overview2061.1 General Information on InterbusInterbus is an open communications standard currently supported by over 200eq

Page 3 - Höhe: 216 mm

Interbus with TSX Momentum Overview7Width: 178 mmHeight: 216 mm201.2 General Information on the 170 INT 110 00Communications Adapter1.2.1 Compatibilit

Page 4

Interbus with TSX Momentum Overview2081.2.2 Environmental SpecificationThe adapter conforms to the environmental specification of the I/O base uponwhi

Page 5

Interbus with TSX Momentum Overview9Width: 178 mmHeight: 216 mm201.2.6 IsolationThe picture shows potential isolation/nonisolation between two I/O mod

Page 6 - Terminology

Interbus with TSX Momentum Overview20101.3 Interbus Configuration with TSX MomentumThe following is a brief summary of the Interbus topology and confi

Page 7 - Related Documents

Interbus with TSX Momentum Overview11Width: 178 mmHeight: 216 mm20Figure 2 Example of an Interbus Configuration with Momentum I/O ModulesNOA 611CPUNod

Page 8

Interbus with TSX Momentum Overview20121.4 Configuration LimitsTable 1 Interbus Configuration Limits for Standard PLC (e.g. TSX Quantum)ParametersLi

Page 9 - Overview

13Width: 178 mmHeight: 216 mm20Communications Adapter RegisterMappingThe following topics will be reviewed in this chapter:H I/O words and ID–codeH Ma

Page 10

Communications Adapter Register Mapping20142.1 I/O words and ID–codeAfter the I/O module is powered–up, the identification code (ID code) of themodule

Page 11 - Communications Adapter

Communications Adapter Register Mapping15Width: 178 mmHeight: 216 mm20Table 3 I/O Base Word Number and ID Codes (discrete I/O bases)DescriptionFuncti

Page 12 - Error Control

Data, Illustrations, AlterationsData and illustrations are not binding. We reserve the right to alter products in linewith our policy of continuous pr

Page 13 - Isolation

Communications Adapter Register Mapping20162.2 Mapping Data Bits to I/O Base Terminals2.2.1 Data Register Mapping for Discrete I/O basesThe data trans

Page 14

Communications Adapter Register Mapping17Width: 178 mmHeight: 216 mm202.2.2 Data Register Mapping for Analog I/O basesData in controller registers is

Page 15 - Width: 178 mm

Communications Adapter Register Mapping2018

Page 16 - Configuration Limits

19Width: 178 mmHeight: 216 mm20Module Description of170 INT 110 00The following topics will be reviewed in this chapter:H Communication Adapter Overvi

Page 17

Module Description of 170 INT 110 0020203.1 Communication Adapter OverviewThe Interbus Communiation Adapter can be operated with any TSX MomentumI/O b

Page 18 - I/O words and ID–code

Module Description of 170 INT 110 0021Width: 178 mmHeight: 216 mm203.2 Preparing the Remote Bus CableModules at inline sites on the Interbus remote bu

Page 19

Module Description of 170 INT 110 002022Modicon provides pre-fabricated Interbus cables in four lengths. Each cable hastwo connectors installed for di

Page 20

Module Description of 170 INT 110 0023Width: 178 mmHeight: 216 mm20Pin WireColorConnectionoutgoingremote busPin WireColorConnectionoutgoingremote bus1

Page 21

Module Description of 170 INT 110 0020243.3 LED Status DisplaysBARCRDTable 5 LED Status DisplaysLEDStatus FunctionBA Green Bus enabled. Data messages

Page 22

Module Description of 170 INT 110 0025Width: 178 mmHeight: 216 mm203.4 Technical SpecificationsGeneralPower consumption < 200 mA at 5 V (supplied b

Page 23 - 170 INT 110 00

ContentIII20Breite: 178 mmHöhe: 216 mmContentPreface 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24 - OUT (sockets)

Module Description of 170 INT 110 002026How to order:Description Part No.Interbus Communication Adapter 170 INT 110 00Remote Bus Cable (sold by the me

Page 25

27Breite: 178 mmHöhe: 216 mm20Appendix

Page 27

29Width: 178 mmHeight: 216 mm20EMC Measures for theCommunications AdapterH Overvoltage Protection for Remote Bus LinesA

Page 28 - LED Status Displays

EMC Measures for the Communications Adapter2030A.1 Overvoltage Protection for Remote Bus Lines(lightning protection)To protect transmission systems fr

Page 29 - Technical Specifications

EMC Measures for the Communications Adapter31Width: 178 mmHeight: 216 mm20Figure 7 Circuit layout and dimensions of the ARE lightning arrestor8835517.

Page 30 - How to order:

EMC Measures for the Communications Adapter2032Figure 8 Schematic of ARE lightning arrestor connectionW1 Remote Bus Line LiYCY (TP)Z2 Grounding clampO

Page 32

Info.50Breite: 178 mmHöhe: 216 mm120PrefaceCautionThe relevant regulations must be observed for control applicatons involvingsafety requirements.For r

Page 33 - EMC Measures for the

Preface202TerminologyNoteThis symbol emphasizes very important facts.CautionThis symbol refers to frequently appearing error sources.WarningThis symbo

Page 34 - (lightning protection)

PrefaceBreite: 178 mmHöhe: 216 mm320Related DocumentsTitle Order–No.I/O Module Bases for TSX Momentum, User Manual 870 USE 002 00Modicon Terminal Bloc

Page 35

Preface204

Page 36 - Building 1 Building 2

5Width: 178 mmHeight: 216 mm20Interbus with TSX MomentumOverviewThe following topics will be reviewed in this chapter:H General information on Interbu

Comments to this Manuals

No comments