Xantrex™ GT250 Grid-Tied Photovoltaic InverterXantrex GT250 480 Xantrex GT250 600Xantrex GT250 480 PG Planning and Installation Manual www.schneider
Safetyviii 153396 Revision DThis manual is for use by qualified installers onlyWARNING: Multiple sources with risk of electric shock, explosion, and a
Safety153396 Revision D ixThis manual is for use by qualified installers onlyRisksGeneral Safety Precautions1. When installing the Xantrex GT250 use o
Safetyx 153396 Revision DThis manual is for use by qualified installers onlyPersonal SafetyFollow these instructions to ensure your safety while worki
Safety153396 Revision D xiThis manual is for use by qualified installers onlyWiring Requirements1. All wiring methods and materials shall be in accord
Safetyxii 153396 Revision DThis manual is for use by qualified installers onlyInverter Isolation TransformerThe Xantrex GT250 includes a custom, high-
Safety153396 Revision D xiiiThis manual is for use by qualified installers onlyLock-out and Tag-out (De-energize/Isolation Procedure)Safety requiremen
Safetyxiv 153396 Revision DThis manual is for use by qualified installers only7. Ensure that all incoming energy sources are de-energized by checking
Safety153396 Revision D xvThis manual is for use by qualified installers only8. Ensure that all incoming energy sources are de-energized by checking t
153396 Revision D xviiThis manual is for use by qualified installers onlyImportant Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - -
Contentsxviii 153396 Revision DThis manual is for use by qualified installers only2 PlanningOverview of Xantrex GT250 Installation - - - - - - - - -
Contents153396 Revision D xixThis manual is for use by qualified installers onlyVerify AC Voltage - - - - - - - - - - - - - - - - - - - - - - - - -
153396 Revision D xxiThis manual is for use by qualified installers onlyFigure 1-1 Main Inverter (Open Enclosure View) - - - - - - - - - - - - - - -
xxii
153396 Revision D xxiiiThis manual is for use by qualified installers onlyTable 1-1 DC Terminal Polarity - - - - - - - - - - - - - - - - - - - - - -
xxiv
153396 Revision D 1–1This manual is for use by qualified installers only1 IntroductionChapter 1, “Introduction” provides information about the feature
Introduction1–2 153396 Revision DThis manual is for use by qualified installers onlyDescription of the Xantrex GT250The Xantrex GT250 Grid-Tied Photov
Physical Characteristics153396 Revision D 1–3This manual is for use by qualified installers onlyPhysical CharacteristicsThe Xantrex GT250 is assembled
Xantrex GT250 Grid-Tied Photovoltaic InverterPlanning and Installation Manual www.schneider-electric.com
Introduction1–4 153396 Revision DThis manual is for use by qualified installers onlyFigure 1-2 Xantrex GT250 Major SectionsPower Electronics sectionIs
Physical Characteristics153396 Revision D 1–5This manual is for use by qualified installers onlyAC InterfaceThe AC interface serves as the connection
Introduction1–6 153396 Revision DThis manual is for use by qualified installers onlyAuxiliary Control InterfaceThe Xantrex GT250 has provisions within
Physical Characteristics153396 Revision D 1–7This manual is for use by qualified installers onlyPower ElectronicsThe Xantrex GT250 power electronics s
Introduction1–8 153396 Revision DThis manual is for use by qualified installers onlyDC TerminalsThe terminals provide seven holes with space for fourt
Physical Characteristics153396 Revision D 1–9This manual is for use by qualified installers onlyHeater FansThe heater fans provide supplementary heat
Introduction1–10 153396 Revision DThis manual is for use by qualified installers onlyCircuit DiagramFigure 1-7 Xantrex GT250 Circuit DiagramCAC GRID3
Operator Interface Controls153396 Revision D 1–11This manual is for use by qualified installers onlyOperator Interface ControlsOperator interface cont
Introduction1–12 153396 Revision DThis manual is for use by qualified installers onlyON/OFF SwitchThe Xantrex GT250 incorporates a maintained position
Operator Interface Controls153396 Revision D 1–13This manual is for use by qualified installers onlyAC Disconnect and DC Disconnect SwitchBoth enclosu
Copyright and ContactTrademarksSchneider Electric, the Schneider Electric logo, and Xantrex are trademarks or registered trademarks of the Schneider E
Introduction1–14 153396 Revision DThis manual is for use by qualified installers onlyFigure 1-10 AC and DC Disconnect SwitchesDC Disconnect switch (S1
Communication Features and Methods153396 Revision D 1–15This manual is for use by qualified installers onlyCommunication Features and MethodsThe Xantr
Introduction1–16 153396 Revision DThis manual is for use by qualified installers onlyFigure 1-11 VFD Display and UFCU LocationUniversal Front Panel Co
Communication Features and Methods153396 Revision D 1–17This manual is for use by qualified installers onlyData LoggingThe Xantrex GT250 inverter stor
Introduction1–18 153396 Revision DThis manual is for use by qualified installers onlyOscillographyThe Xantrex GT250 includes a graphic data analysis t
153396 Revision D 2–1This manual is for use by qualified installers only2 PlanningChapter 2, “Planning” provides information to help plan the installa
Planning2–2 153396 Revision DThis manual is for use by qualified installers onlyOverview of Xantrex GT250 InstallationPlanning Planning for a system r
PV Planning153396 Revision D 2–3This manual is for use by qualified installers onlyPV PlanningTo determine the number of photovoltaic panels that are
Planning2–4 153396 Revision DThis manual is for use by qualified installers onlyGround RequirementsThis product is intended to be installed as part of
Electrical Diagrams153396 Revision D 2–5This manual is for use by qualified installers onlyElectrical DiagramsSince installations vary widely, a sampl
153396 Revision D iiiThis manual is for use by qualified installers onlyAbout This ManualPurposeThe purpose of this Planning and Installation Manual i
Planning2–6 153396 Revision DThis manual is for use by qualified installers onlyConduit EntryFor a typical Xantrex GT250 installation, the recommended
Conduit Entry153396 Revision D 2–7This manual is for use by qualified installers onlyFigure 2-3 Conduit Entries Above Ground, Multiple ViewsAC interfa
Planning2–8 153396 Revision DThis manual is for use by qualified installers onlyAnchoring the Xantrex GT250The Xantrex GT250 must be anchored to a lev
153396 Revision D 3–1This manual is for use by qualified installers only3 InstallationChapter 3, “Installation” describes the procedures needed to ins
Installation3–2 153396 Revision DThis manual is for use by qualified installers onlyUnloadingMoving the Xantrex GT250To move the Xantrex GT250, use a
Unloading153396 Revision D 3–3This manual is for use by qualified installers onlyRemoving the Pallet and Moving the Xantrex GT250Use Figure 3-1 to loc
Installation3–4 153396 Revision DThis manual is for use by qualified installers onlyMoving with a SlingTo move the Xantrex GT250 using a sling:1. Plac
Unloading153396 Revision D 3–5This manual is for use by qualified installers onlyRemoving the Air Intake DuctThe Air Intake Duct may be removed from t
Installation3–6 153396 Revision DThis manual is for use by qualified installers onlyMounting and Anchoring the UnitsTo mount and anchor the Xantrex GT
Opening or Closing Access Doors153396 Revision D 3–7This manual is for use by qualified installers onlyOpening or Closing Access DoorsFigure 3-5 AC In
About This Manualiv 153396 Revision DThis manual is for use by qualified installers onlyOrganizationThis Manual is organized into five chapters and tw
Installation3–8 153396 Revision DThis manual is for use by qualified installers onlyWiring - General RequirementsAll wiring methods and materials shal
Wiring - General Requirements153396 Revision D 3–9This manual is for use by qualified installers onlyOvercurrent ProtectionUnless provided as part of
Installation3–10 153396 Revision DThis manual is for use by qualified installers onlyGroundingSystem Grounding This product is intended to be installe
Connecting the Conductors153396 Revision D 3–11This manual is for use by qualified installers onlyConnecting the ConductorsThis section provides infor
Installation3–12 153396 Revision DThis manual is for use by qualified installers onlyFigure 3-8 AC Terminal Connections from the UtilityFigure 3-9 Aux
Connecting the Conductors153396 Revision D 3–13This manual is for use by qualified installers onlyPV Wiring to the DC InterfaceTo make the connections
Installation3–14 153396 Revision DThis manual is for use by qualified installers onlyRemote CommunicationsThe Xantrex GT250 has the ability to provide
153396 Revision D 4–1This manual is for use by qualified installers only4 VerificationChapter 4, “Verification” provides a checklist to ensure the ins
Verification4–2 153396 Revision DThis manual is for use by qualified installers onlyVerification Procedure SummaryThe following procedures are intende
Visual Inspection of Mechanical Connections153396 Revision D 4–3This manual is for use by qualified installers onlyVisual Inspection of Mechanical Con
About This Manual153396 Revision D vThis manual is for use by qualified installers onlyXantrex GT250 ModelsThis Planning and Installation Manual conta
153396 Revision D 5–1This manual is for use by qualified installers only5 CommissioningChapter 5, “Commissioning” contains information for qualified p
Commissioning5–2 153396 Revision DThis manual is for use by qualified installers onlyCommissioning ProcedureThis section provides the procedure necess
Starting the Commissioning Test153396 Revision D 5–3This manual is for use by qualified installers onlyStarting the Commissioning TestSerial NumberEnt
Commissioning5–4 153396 Revision DThis manual is for use by qualified installers onlyApply Grid Voltage1. Verify both Xantrex GT250 inverter enclosure
Starting the Commissioning Test153396 Revision D 5–5This manual is for use by qualified installers onlyApply DC Voltage1. Verify both Xantrex GT250 in
Commissioning5–6 153396 Revision DThis manual is for use by qualified installers onlyRevised Protection Settings (If Required)1. If default protection
153396 Revision D A–1This manual is for use by qualified installers onlyA SpecificationsAppendix A provides the environmental and electrical specifica
SpecificationsA–2 153396 Revision DThis manual is for use by qualified installers onlySystem SpecificationsThe Xantrex GT250 has been designed for pho
System Specifications153396 Revision D A–3This manual is for use by qualified installers onlyElectrical SpecificationsTable A-2 provides the AC and DC
About This Manualvi 153396 Revision DThis manual is for use by qualified installers onlyAbbreviations and AcronymsRelated InformationYou can find more
SpecificationsA–4 153396 Revision DThis manual is for use by qualified installers onlyOver Voltage, Under Voltage and Frequency RangesTable A-4 provid
System Specifications153396 Revision D A–5This manual is for use by qualified installers onlyArc Flash InformationUse the following short circuit info
SpecificationsA–6 153396 Revision DThis manual is for use by qualified installers onlyBolt Sizing and Torque RequirementsTable A-6 provides acceptable
Dimensions153396 Revision D A–7This manual is for use by qualified installers onlyDimensionsFigure A-1 Xantrex GT250 Dimensions2192.0 mm(86.3 in)2286.
153396 Revision D B–1This manual is for use by qualified installers onlyB Commissioning Test RecordAppendix B contains the Commissioning Test Record f
Commissioning Test Record153396 Revision D B–3This manual is for use by qualified installers onlyCommissioning Test RecordStep 1. Record and Document
Commissioning Test RecordB–4 153396 Revision DThis manual is for use by qualified installers onlyI hereby undertake that the Xantrex GT250 inverter re
153396 Revision D IX-1This manual is for use by qualified installers onlyAAbbreviations and Acronyms viAC Interface 1–5AC Interface Enclosure 1–6AC U
153396 Revision D viiThis manual is for use by qualified installers onlyImportant Safety InstructionsREAD AND SAVE THESE INSTRUCTIONS - DO NOT DISCARD
IndexIX–2 153396 Revision DThis manual is for use by qualified installers onlyON/OFF Switch 1–12Operational Safety xiiOperator Interface Controls 1–1
153396Printed in USASchneider Electricwww.schneider-electric.com ☎✉North America 1 408 987 6255 1 925 245 1022 [email protected]
Comments to this Manuals