Schneider Electric Xant Installation Manual

Browse online or download Installation Manual for Power adapters & inverters Schneider Electric Xant. Schneider Electric Xant Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 92
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Xantrex™ GT250
Grid-Tied Photovoltaic Inverter
Xantrex GT250 480 Xantrex GT250 600
Xantrex GT250 480 PG
Planning and Installation Manual
www.schneider-electric.com
Page view 0
1 2 3 4 5 6 ... 91 92

Summary of Contents

Page 1 - Xantrex™ GT250

Xantrex™ GT250 Grid-Tied Photovoltaic InverterXantrex GT250 480 Xantrex GT250 600Xantrex GT250 480 PG Planning and Installation Manual www.schneider

Page 2

Safetyviii 153396 Revision DThis manual is for use by qualified installers onlyWARNING: Multiple sources with risk of electric shock, explosion, and a

Page 3 - Xantrex GT250

Safety153396 Revision D ixThis manual is for use by qualified installers onlyRisksGeneral Safety Precautions1. When installing the Xantrex GT250 use o

Page 4 - Copyright and Contact

Safetyx 153396 Revision DThis manual is for use by qualified installers onlyPersonal SafetyFollow these instructions to ensure your safety while worki

Page 5 - About This Manual

Safety153396 Revision D xiThis manual is for use by qualified installers onlyWiring Requirements1. All wiring methods and materials shall be in accord

Page 6 - Conventions Used

Safetyxii 153396 Revision DThis manual is for use by qualified installers onlyInverter Isolation TransformerThe Xantrex GT250 includes a custom, high-

Page 7 - Xantrex GT250 Models

Safety153396 Revision D xiiiThis manual is for use by qualified installers onlyLock-out and Tag-out (De-energize/Isolation Procedure)Safety requiremen

Page 8 - Related Information

Safetyxiv 153396 Revision DThis manual is for use by qualified installers only7. Ensure that all incoming energy sources are de-energized by checking

Page 9 - Important Safety Instructions

Safety153396 Revision D xvThis manual is for use by qualified installers only8. Ensure that all incoming energy sources are de-energized by checking t

Page 11 - General Safety Precautions

153396 Revision D xviiThis manual is for use by qualified installers onlyImportant Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - -

Page 13 - Wiring Requirements

Contentsxviii 153396 Revision DThis manual is for use by qualified installers only2 PlanningOverview of Xantrex GT250 Installation - - - - - - - - -

Page 14 - Operational Safety Procedures

Contents153396 Revision D xixThis manual is for use by qualified installers onlyVerify AC Voltage - - - - - - - - - - - - - - - - - - - - - - - - -

Page 16 - TB2 Ground bar

153396 Revision D xxiThis manual is for use by qualified installers onlyFigure 1-1 Main Inverter (Open Enclosure View) - - - - - - - - - - - - - - -

Page 18

153396 Revision D xxiiiThis manual is for use by qualified installers onlyTable 1-1 DC Terminal Polarity - - - - - - - - - - - - - - - - - - - - - -

Page 20 - 5 Commissioning

153396 Revision D 1–1This manual is for use by qualified installers only1 IntroductionChapter 1, “Introduction” provides information about the feature

Page 21 - B Commissioning Test Record

Introduction1–2 153396 Revision DThis manual is for use by qualified installers onlyDescription of the Xantrex GT250The Xantrex GT250 Grid-Tied Photov

Page 22

Physical Characteristics153396 Revision D 1–3This manual is for use by qualified installers onlyPhysical CharacteristicsThe Xantrex GT250 is assembled

Page 23

Xantrex GT250 Grid-Tied Photovoltaic InverterPlanning and Installation Manual www.schneider-electric.com

Page 24

Introduction1–4 153396 Revision DThis manual is for use by qualified installers onlyFigure 1-2 Xantrex GT250 Major SectionsPower Electronics sectionIs

Page 25

Physical Characteristics153396 Revision D 1–5This manual is for use by qualified installers onlyAC InterfaceThe AC interface serves as the connection

Page 26

Introduction1–6 153396 Revision DThis manual is for use by qualified installers onlyAuxiliary Control InterfaceThe Xantrex GT250 has provisions within

Page 27 - 1 Introduction

Physical Characteristics153396 Revision D 1–7This manual is for use by qualified installers onlyPower ElectronicsThe Xantrex GT250 power electronics s

Page 28 - Advanced Design Features

Introduction1–8 153396 Revision DThis manual is for use by qualified installers onlyDC TerminalsThe terminals provide seven holes with space for fourt

Page 29 - Physical Characteristics

Physical Characteristics153396 Revision D 1–9This manual is for use by qualified installers onlyHeater FansThe heater fans provide supplementary heat

Page 30 - 1–4 153396 Revision D

Introduction1–10 153396 Revision DThis manual is for use by qualified installers onlyCircuit DiagramFigure 1-7 Xantrex GT250 Circuit DiagramCAC GRID3

Page 31 - AC Interface

Operator Interface Controls153396 Revision D 1–11This manual is for use by qualified installers onlyOperator Interface ControlsOperator interface cont

Page 32 - Communications Circuit

Introduction1–12 153396 Revision DThis manual is for use by qualified installers onlyON/OFF SwitchThe Xantrex GT250 incorporates a maintained position

Page 33 - DC Interface

Operator Interface Controls153396 Revision D 1–13This manual is for use by qualified installers onlyAC Disconnect and DC Disconnect SwitchBoth enclosu

Page 34 - DC Terminals

Copyright and ContactTrademarksSchneider Electric, the Schneider Electric logo, and Xantrex are trademarks or registered trademarks of the Schneider E

Page 35 - Heater Fans

Introduction1–14 153396 Revision DThis manual is for use by qualified installers onlyFigure 1-10 AC and DC Disconnect SwitchesDC Disconnect switch (S1

Page 36 - Circuit Diagram

Communication Features and Methods153396 Revision D 1–15This manual is for use by qualified installers onlyCommunication Features and MethodsThe Xantr

Page 37 - Operator Interface Controls

Introduction1–16 153396 Revision DThis manual is for use by qualified installers onlyFigure 1-11 VFD Display and UFCU LocationUniversal Front Panel Co

Page 38 - Auxiliary ENABLE/DISABLE

Communication Features and Methods153396 Revision D 1–17This manual is for use by qualified installers onlyData LoggingThe Xantrex GT250 inverter stor

Page 39 - N position

Introduction1–18 153396 Revision DThis manual is for use by qualified installers onlyOscillographyThe Xantrex GT250 includes a graphic data analysis t

Page 40 - 1–14 153396 Revision D

153396 Revision D 2–1This manual is for use by qualified installers only2 PlanningChapter 2, “Planning” provides information to help plan the installa

Page 41

Planning2–2 153396 Revision DThis manual is for use by qualified installers onlyOverview of Xantrex GT250 InstallationPlanning Planning for a system r

Page 42 - 1–16 153396 Revision D

PV Planning153396 Revision D 2–3This manual is for use by qualified installers onlyPV PlanningTo determine the number of photovoltaic panels that are

Page 43 - Data Logging

Planning2–4 153396 Revision DThis manual is for use by qualified installers onlyGround RequirementsThis product is intended to be installed as part of

Page 44 - Optional Equipment

Electrical Diagrams153396 Revision D 2–5This manual is for use by qualified installers onlyElectrical DiagramsSince installations vary widely, a sampl

Page 45

153396 Revision D iiiThis manual is for use by qualified installers onlyAbout This ManualPurposeThe purpose of this Planning and Installation Manual i

Page 46

Planning2–6 153396 Revision DThis manual is for use by qualified installers onlyConduit EntryFor a typical Xantrex GT250 installation, the recommended

Page 47 - Environmental Requirements

Conduit Entry153396 Revision D 2–7This manual is for use by qualified installers onlyFigure 2-3 Conduit Entries Above Ground, Multiple ViewsAC interfa

Page 48 - System Neutral Requirements

Planning2–8 153396 Revision DThis manual is for use by qualified installers onlyAnchoring the Xantrex GT250The Xantrex GT250 must be anchored to a lev

Page 49

153396 Revision D 3–1This manual is for use by qualified installers only3 InstallationChapter 3, “Installation” describes the procedures needed to ins

Page 50

Installation3–2 153396 Revision DThis manual is for use by qualified installers onlyUnloadingMoving the Xantrex GT250To move the Xantrex GT250, use a

Page 51 - 153396 Revision D 2–7

Unloading153396 Revision D 3–3This manual is for use by qualified installers onlyRemoving the Pallet and Moving the Xantrex GT250Use Figure 3-1 to loc

Page 52

Installation3–4 153396 Revision DThis manual is for use by qualified installers onlyMoving with a SlingTo move the Xantrex GT250 using a sling:1. Plac

Page 53

Unloading153396 Revision D 3–5This manual is for use by qualified installers onlyRemoving the Air Intake DuctThe Air Intake Duct may be removed from t

Page 54 - Unloading

Installation3–6 153396 Revision DThis manual is for use by qualified installers onlyMounting and Anchoring the UnitsTo mount and anchor the Xantrex GT

Page 55 -  symbol)

Opening or Closing Access Doors153396 Revision D 3–7This manual is for use by qualified installers onlyOpening or Closing Access DoorsFigure 3-5 AC In

Page 56 - Moving with a Sling

About This Manualiv 153396 Revision DThis manual is for use by qualified installers onlyOrganizationThis Manual is organized into five chapters and tw

Page 57 - Removing the Air Intake Duct

Installation3–8 153396 Revision DThis manual is for use by qualified installers onlyWiring - General RequirementsAll wiring methods and materials shal

Page 58 - WARNING: Fire hazard

Wiring - General Requirements153396 Revision D 3–9This manual is for use by qualified installers onlyOvercurrent ProtectionUnless provided as part of

Page 59 - FF (Open)

Installation3–10 153396 Revision DThis manual is for use by qualified installers onlyGroundingSystem Grounding This product is intended to be installe

Page 60 - Wiring - General Requirements

Connecting the Conductors153396 Revision D 3–11This manual is for use by qualified installers onlyConnecting the ConductorsThis section provides infor

Page 61 - WARNING: Risk of fire

Installation3–12 153396 Revision DThis manual is for use by qualified installers onlyFigure 3-8 AC Terminal Connections from the UtilityFigure 3-9 Aux

Page 62 - System Neutral

Connecting the Conductors153396 Revision D 3–13This manual is for use by qualified installers onlyPV Wiring to the DC InterfaceTo make the connections

Page 63 - Connecting the Conductors

Installation3–14 153396 Revision DThis manual is for use by qualified installers onlyRemote CommunicationsThe Xantrex GT250 has the ability to provide

Page 64 - 3–12 153396 Revision D

153396 Revision D 4–1This manual is for use by qualified installers only4 VerificationChapter 4, “Verification” provides a checklist to ensure the ins

Page 65 - PV Wiring to the DC Interface

Verification4–2 153396 Revision DThis manual is for use by qualified installers onlyVerification Procedure SummaryThe following procedures are intende

Page 66 - Remote Communications

Visual Inspection of Mechanical Connections153396 Revision D 4–3This manual is for use by qualified installers onlyVisual Inspection of Mechanical Con

Page 67

About This Manual153396 Revision D vThis manual is for use by qualified installers onlyXantrex GT250 ModelsThis Planning and Installation Manual conta

Page 69 - Corrective Action

153396 Revision D 5–1This manual is for use by qualified installers only5 CommissioningChapter 5, “Commissioning” contains information for qualified p

Page 70

Commissioning5–2 153396 Revision DThis manual is for use by qualified installers onlyCommissioning ProcedureThis section provides the procedure necess

Page 71

Starting the Commissioning Test153396 Revision D 5–3This manual is for use by qualified installers onlyStarting the Commissioning TestSerial NumberEnt

Page 72 - Commissioning Procedure

Commissioning5–4 153396 Revision DThis manual is for use by qualified installers onlyApply Grid Voltage1. Verify both Xantrex GT250 inverter enclosure

Page 73

Starting the Commissioning Test153396 Revision D 5–5This manual is for use by qualified installers onlyApply DC Voltage1. Verify both Xantrex GT250 in

Page 74 - Front Panel Display

Commissioning5–6 153396 Revision DThis manual is for use by qualified installers onlyRevised Protection Settings (If Required)1. If default protection

Page 75 - Functional Test

153396 Revision D A–1This manual is for use by qualified installers onlyA SpecificationsAppendix A provides the environmental and electrical specifica

Page 76 - Completed Commissioning

SpecificationsA–2 153396 Revision DThis manual is for use by qualified installers onlySystem SpecificationsThe Xantrex GT250 has been designed for pho

Page 77

System Specifications153396 Revision D A–3This manual is for use by qualified installers onlyElectrical SpecificationsTable A-2 provides the AC and DC

Page 78 - System Specifications

About This Manualvi 153396 Revision DThis manual is for use by qualified installers onlyAbbreviations and AcronymsRelated InformationYou can find more

Page 79 - Regulatory Specifications

SpecificationsA–4 153396 Revision DThis manual is for use by qualified installers onlyOver Voltage, Under Voltage and Frequency RangesTable A-4 provid

Page 80

System Specifications153396 Revision D A–5This manual is for use by qualified installers onlyArc Flash InformationUse the following short circuit info

Page 81 - Arc Flash Information

SpecificationsA–6 153396 Revision DThis manual is for use by qualified installers onlyBolt Sizing and Torque RequirementsTable A-6 provides acceptable

Page 82 - NABLE/DISABLE

Dimensions153396 Revision D A–7This manual is for use by qualified installers onlyDimensionsFigure A-1 Xantrex GT250 Dimensions2192.0 mm(86.3 in)2286.

Page 84

153396 Revision D B–1This manual is for use by qualified installers onlyB Commissioning Test RecordAppendix B contains the Commissioning Test Record f

Page 86

Commissioning Test Record153396 Revision D B–3This manual is for use by qualified installers onlyCommissioning Test RecordStep 1. Record and Document

Page 87 - Commissioning Test Record

Commissioning Test RecordB–4 153396 Revision DThis manual is for use by qualified installers onlyI hereby undertake that the Xantrex GT250 inverter re

Page 88 -  to 100 %: Yes 

153396 Revision D IX-1This manual is for use by qualified installers onlyAAbbreviations and Acronyms viAC Interface 1–5AC Interface Enclosure 1–6AC U

Page 89

153396 Revision D viiThis manual is for use by qualified installers onlyImportant Safety InstructionsREAD AND SAVE THESE INSTRUCTIONS - DO NOT DISCARD

Page 90

IndexIX–2 153396 Revision DThis manual is for use by qualified installers onlyON/OFF Switch 1–12Operational Safety xiiOperator Interface Controls 1–1

Page 92 - Schneider Electric

153396Printed in USASchneider Electricwww.schneider-electric.com ☎✉North America 1 408 987 6255 1 925 245 1022 [email protected]

Comments to this Manuals

No comments