Heat Pump (2-Stage Heat / 1-Stage Cool)
Configuration
The “System Type” for this thermostat must be set to “Heat Pump” under “System Options.”
The “System Type” for this thermostat must be set to “Dual Fuel Heat Pump” for a dual fuel system
(Terminal “W2” is connected to the “W” or “W1” on the furnace).
Power Up
1. Double check the wiring. Be sure there are no stray wires or wire strands at the connections.
2. Turn on power to the transformer and system. The display will show the current thermostat
settings.
3. Press [TEMP], then press [MORE].
4. Scroll to Fan and press [OK].
5. Set the fan to On. Press [OK] and then press [Back]. The fan should turn on.
6. Navigate back to the Fan screen and set the fan to Auto. Press [OK] and then press [Back]. The
fan should turn off.
7. Press [HOLD] and select On to override Energy Efficient Control.
8. Press [MORE], scroll to Mode, and press [OK]. Set the mode to Heat. Press [OK] and then press
[Back].
9. Raise the desired heat setting 1 degree above the current temperature. Ensure that the heat pump
turns on in heating mode. After a few minutes, raise the desired heat setting 3 degrees above the
current temperature. Auxiliary heat should turn on. After a few minutes, set the mode to “EM Heat”.
The heat pump should stop, but the auxiliary heat should remain on.
10. Navigate back to the Mode screen and set the mode to Off. Press [OK] and then press [Back].
Ensure that both the heat pump and auxiliary heat turn off.
Figure 8: Connections for Heat Pump Thermostat
24 Vac Common*
24 Vac "HOT"
Auxiliary Heat
Compressor
Ground Fault
Humidifier
Fan
Dehumidifier
Compressor Relay
Aux Heat Relay
Fan Relay
Humidifier
Fault Relay
Dehumidifier
Reversing Valve
Energized in Cool
Energized in Heat
24 VAC
CONTROL
TRANSFORMER
THERMOSTAT
UP
HVAC SYSTEM
12
11
7
6
8
3
1
(D)
(H)
(G)
(Y1)
(B)
(C)
(RC)
4
5
9
(O)
(W2)
(L)