Power Up
1. Double check the wiring. Be sure there are no stray wires or wire strands at the connections.
2. Turn on power to the transformer and system. The display will show the current thermostat
settings.
3. Press [TEMP], then press [MORE].
4. Scroll to Fan and press [OK].
5. Set the fan to On. Press [OK] and then press [Back]. The fan should turn on.
6. Navigate back to the Fan screen and set the fan to Auto. Press [OK] and then press [Back]. The
fan should turn off.
7. Press [MORE], scroll to Mode, and press [OK]. Set the mode to Heat. Press [OK] and then press
[Back].
8. Raise the desired heat setting above the current temperature. Ensure that the heating unit turns on.
9. Navigate back to the Mode screen and set the mode to Off. Press [OK] and then press [Back]. The
heating unit should turn off.
10. Navigate back to the Mode screen and set the mode to Cool. Press [OK] and then press [Back].
Lower the desired cool setting below the current temperature. Ensure that the cooling unit turns on.
11. Navigate back to the Mode screen and set the mode to Off. Press [OK] and then press [Back].
Ensure that the cooling unit turns off.
12. Navigate back to the Mode screen and set the mode to Auto. Press [OK] and then press [Back].
The EER56100 thermostat works with most single-stage conventional 4-wire HVAC systems (without a
transformer common). However, if the thermostat resets when calling for heat or cool, or if the heat, cool,
or fan relay cannot supply 15 mA to power thermostat without the relay activating, the transformer
common wire or the Wiser Thermostat Auxiliary Power Supply (Part Number EER57100) is required.
Single-Stage Conventional for Zone Control Systems
Figure 6: Connections for Single-Stage Thermostat for Zone Control Systems
(W2)
4
(Y2)
(D)
(H)
(G)
(Y1)
(W1)
(C)
(RC)
10
1
3
8
6
7
11
12
ZONE CONTROLLER
THERMOSTAT
Dehumidifier
Humidifier
System Cool Mode
Fan Relay
Zone Cool
Zone Heat
System Heat Mode
24 VAC
CONTROL
TRANSFORMER
Fan
Cool
Cool Mode
Humidifier
Dehumidifier
24 Vac "HOT"
24 Vac Common
Heat Mode
Heat